Performance Data
Venturi & Packed Tower Combination versus TURBOSCRUBBER
(A Real Case Comparison
of Equivalent Efficiency Systems)
SYSTEM OPERATING
DETAILS
|
TURBOSCRUBBER
|
VENTURI/PACKED
TOWER
|
LIQUID MEDIUM
|
SEAWATER
OR 35% W/W KCI SLURRIES
|
SEAWATER
ONLY
|
SO2
REMOVAL
|
99.8%
|
99.8%
|
KCI/C PARTICULATE
REMOVAL @ 1.7 MICRON
|
99%
|
99%
|
PRESSURE
DROP
|
6.4"
W.G.
|
15"
W.G.
|
RELATIVE
VOLUME (APPROX)
|
1.0
|
5.0
|
PLUGGING/CLOGGING
|
NO
|
YES
|
SLURRY HEAT
RECOVERY RATE
|
4.2MW
|
NONE POSSIBLE
|
A Typical Packed Tower Absorber
Versus TURBOSCRUBBER
TOWER TYPE
|
TURBOSCRUBBER
|
FIXED PACK
|
PACKING
|
TURBOID
|
TYPICAL
2" RING
|
H2S REMOVAL
|
99.997
|
99.997
|
TYPICAL
DIAMETER
|
1.25 METER
|
1.75 METER
|
ABSORBTION
ZONE HEIGHT
|
2 METERS
|
7 METERS
(FIXED)
|
PRESSURE
DROP (APPROX)
|
6"
W.G
|
6"
W.G
|
PARTICLE
REMOVAL @1.0 MICRON SIZE
|
>85%
|
BLOCKAGE
|
Generalised HTU Comparisons